INPUT SPECIFICATION |
Voltage Range |
100-120VAC |
200-240VAC |
Frequency Range |
47-63Hz |
Efficiency |
MS-25-5: 70% |
MS-25-12: 70% |
MS-25-24: 78% |
AC Current(typ.) |
0.35A / 230VAC |
Inrush Current(typ.) |
30A / 230VAC (for cold start at 250C) |
Leakage Current |
<0.5mA / 240VAC |
|
|
OUTPUT SPECIFICATION |
Rated Current |
MS-25-5: 5.0A |
MS-25-12: 2.1A |
MS-25-24: 1.1A |
Rated Power |
25Watts |
Voltage ADJ. Range |
10% (with V.ADJ) |
Voltage Tolerance |
1% |
Ripple & Noise(Max) |
MS-25-5: 100mVp-p |
MS-25-12: 100mVp-p |
MS-25-24: 150mVp-p |
Setup Time |
200ms / 230VAC |
Rise Time |
50ms / 230VAC |
Hold Time(typ.) |
20ms / 230VAC |
|
|
PROTECTION |
Overload |
100% to 110% rated load current |
Protection Type: Hiccup mode, Recovers Automatically after fault condition is removed |
Overvoltage |
Protection Type: Shutdown output voltage, re-power on to recover |
|
|
ENVIRONMENT |
Working Temperature |
-100C to 600C (derating is required according to temperature) |
Working Humidity |
20% to 90% RH |
Storage Temperature |
-200C to 850C (with no icing or condensation) |
Storage Humidity |
10% ~ 95% RH |
Vibration Resistance |
10 to 500Hz, 10min/1cycle (2G) for 60 minutes each in X,Y,Z directions |
|
|
SECURITY |
Isolation Resistance |
I/P and O/P ; I/P and FG ; O/P and FG :100MΩ at 500VDC, 250C,70% RH |
Dielectric Strength |
Between I/P and O/P : 1.5kVAC for 1 min |
Between I/P and F.G : 1.5kVAC for 1 min |
Between O/P and F.G : 0.5kVAC for 1 min |
|
|
STANDARDS |
Safety Standards |
Accord with UL1012 |
EMC Standards |
Meet the FCC PART15J Equipment Condition B |