PROTECTION |
Overload |
110% to 140% rated load current |
Protection Type: Hiccup mode, Recovers Automatically after fault condition is removed |
Overvoltage |
Protection Type: Shutdown output voltage, re-power on to recover |
|
|
ENVIRONMENT |
Working Temperature |
-300C to 700C (derating is required according to temperature) |
Working Humidity |
20% to 90% RH |
Storage Temperature |
-400C to 850C (with no icing or condensation) |
Storage Humidity |
10% ~ 95% RH |
Temperature Coefficient |
0.03% 0C (0-50 0C) |
Vibration Resistance |
10 to 500Hz, 10min/1cycle (2G) for 60 minutes each in X,Y,Z directions |
|
|
SECURITY |
Isolation Resistance |
I/P and O/P ; I/P and FG ; O/P and FG :100MΩ at 500VDC, 250C, 70% RH |
Dielectric Strength |
Between I/P and O/P : 1.5kVAC for 1 min |
Between I/P and F.G : 1.5kVAC for 1 min |
Between O/P and F.G : 0.5kVAC for 1 min |
|
|
STANDARDS |
Safety Standards |
Meet the ULGB4943, UL60950, EN60950 |
EMC Standards |
Meet the EN55022, EN61000-3-2, EN61000-3-3, EN55024, GB9254 CLASS B Equipment |